Raypak heater "Rollout SW Open" (2024)

tlwilson

0

LifeTime Supporter

Aug 15, 2010
50
Nebraska
  • May 18, 2013
  • Add bookmark
  • #1

We bought a new heater this season, a Raypak 206,000 BTU NG Electric Heater RHM-15-9962. It heated the pool nicely earlier in the week, but we turned it off when a cool spell was forecast. This morning I tried to turn it on and I get this error message: "Rollout SW Open". What does this mean? I appreciate the help.

JasonLion

0

TFP Expert

Platinum Supporter

LifeTime Supporter

May 7, 2007
37,770
Silver Spring, MD
  • May 18, 2013
  • Add bookmark
  • #2

Here is what I found in the manual: Roll Out Sw Open - Rollout Switch - verify gas pressure, combustion air, blocked heat exchanger, proper vent size/connections, high wind conditions.

ps0303

0

TFP Expert

In The Industry

Jul 6, 2011
4,177
FL
  • May 19, 2013
  • Add bookmark
  • #3

The rollout switch is activated when something like wind causes the flames to shoot out towards the front of the unit. This is usually caused by high winds while the unit is running. Are you sure it it said rollout? Sounds odd that you turn it on and the switch is open.

The rollout switch connects inside the cabinet right behind where the gas pipe comes into the gas valve. I have seen a few cases where the installer moved the rollout switch so they could install the gas pipe and they failed to put it back in place. This dangling switch is right by the burners then and when the units lights, its possible for the switch to trip open.

In any case this unit is under warranty. Hopefully your installer is also a warranty person for Raypak. Call them and have them come back and look at why the switch failed.

tlwilson

0

LifeTime Supporter

Aug 15, 2010
50
Nebraska
  • May 19, 2013
  • Add bookmark
  • #4

Thank you for your reply. It definitely says "Rollout SW Open". I will call the installer for the repair.

tlwilson

0

LifeTime Supporter

Aug 15, 2010
50
Nebraska
  • Jun 14, 2013
  • Add bookmark
  • #5

Our heater is still not fixed. They determined it wasn't getting enough gas so the gas company replaced our meter. Turned it on and the same thing happened. Now they say the wind diminished the flame and did something to the fireman's switch. Fireman's switch replaced and the wind keeps blowing out or diminishing the flame. Back and forth on how to protect it from the wind. Anybody with advice?

ps0303

0

TFP Expert

In The Industry

Jul 6, 2011
4,177
FL
  • Jun 15, 2013
  • Add bookmark
  • #6

The only thing you can do is add a wind stack to it. You've never had this issue before wind?

tlwilson

0

LifeTime Supporter

Aug 15, 2010
50
Nebraska
  • Jun 15, 2013
  • Add bookmark
  • #7

Our previous heater never had this problem. It was old and inefficient (still worked), but we wanted to upgrade. Raypak heater "Rollout SW Open" (8)

ps0303

0

TFP Expert

In The Industry

Jul 6, 2011
4,177
FL
  • Jun 15, 2013
  • Add bookmark
  • #8

Add the Raypak high wind stack. Probably $100 or around there.

tlwilson

0

LifeTime Supporter

Aug 15, 2010
50
Nebraska
  • Jun 15, 2013
  • Add bookmark
  • #9

Thanks for the help. I appreciate it!

B

[emailprotected]

0
Aug 26, 2014
1
Pensacola Florida
  • Aug 26, 2014
  • Add bookmark
  • #10

How did you solve the problem

Enjoying this content?

Support TFP with a donation.

Give Support

Jun 6, 2013
898
IL
  • Aug 26, 2014
  • Add bookmark
  • #11

I wonder if you have a bad roll out switch. My old RP2100 heater had a wax one and I replaced it with a solid state one. It had a red reset button on it. That solved my roll out problem at the time. They also sell roll out switches that have different shutoff temps by about 10-15deg if I remember but you may not want to go there. I did buy one of the solid state versions which was higher but didn't need it.

J

Jayryght

0
Aug 19, 2016
11
Toronto, Canada
  • Aug 19, 2016
  • Add bookmark
  • #12

I have the same problem. Just happened to me today. I bought and got my heater installed in October 2013 and it heated the pool really nicely. I haven't used the heater in about a week. It's been really hot in Toronto. Today I wanted to do an evening swim with the kids and my wife so I thought I'd turn it on and had the "Rollout SW Opem" message. I thought it was a glitch so I cut the power to the unit and turned it back on, cut the gas and turned it back on, opened up the panel and cleaned any debris I could with a cloth rag and nothing. After reading the comments here I have located the switch but it does not have a reset button. I read somewhere that the newer models do not have one. Is it time to call for service or is there anything else I can do on my end? RSVP

Pool Clown

In The Industry

Sep 5, 2008
2,186
Silicon Valley, CA
  • Aug 20, 2016
  • Add bookmark
  • #13

If it is a Raypak heater, the roll out sensor is a one time use part, like a fuse, it isnt re-settable. I would replace it, leave the front cover removed, start the heater, and observe if the flame "rolls out". If you see this happen, turn off the heater immediately, and have a tech check the exchanger for sooting.

J

Jayryght

0
Aug 19, 2016
11
Toronto, Canada
  • Aug 20, 2016
  • Add bookmark
  • #14

Pool Clown said:

If it is a Raypak heater, the roll out sensor is a one time use part, like a fuse, it isnt re-settable. I would replace it, leave the front cover removed, start the heater, and observe if the flame "rolls out". If you see this happen, turn off the heater immediately, and have a tech check the exchanger for sooting.

I tried that. It doesn't even ignite. Nothing happens. It is just the error message.

wjr75

0

LifeTime Supporter

Jun 6, 2013
898
IL
  • Aug 20, 2016
  • Add bookmark
  • #15

You can jumper across the roll out sensor to see if it starts. This is just for testing purposes and shouldn't be left that way. Might have blown the replaced sensor again or may have some other board issue.

Pool Clown

In The Industry

Sep 5, 2008
2,186
Silicon Valley, CA
  • Aug 20, 2016
  • Add bookmark
  • #16

Jayryght said:

I tried that. It doesn't even ignite. Nothing happens. It is just the error message.

Did you replace the roll out sensor?
Trace the roll out sensors' wires all the way back to the board to make sure they haven't been chewed on.

J

Jayryght

0
Aug 19, 2016
11
Toronto, Canada
  • Aug 20, 2016
  • Add bookmark
  • #17

Re: Raypak heater "Rollout SW Open"

@wjr75 How do I do that? "Jumper across the rollout sensor?"

- - - Updated - - -

@pool clown: no I did not replace it. Not sure how to do that? I see the wires tracing up towards panel, but I guess I have to take off the panel to see it's source right?

- - - Updated - - -

@pool clown: no I did not replace it. Not sure how to do that? I see the wires tracing up towards panel, but I guess I have to take off the panel to see it's source right?

wjr75

0

LifeTime Supporter

Jun 6, 2013
898
IL
  • Aug 20, 2016
  • Add bookmark
  • #18

To jumper across you need a wire across the two terminals where the fuse (roll out sensor) is plugged into. If you do any electrical testing you usually have an alligator clip jumper wire which has one on both ends. But as said before this would be temporary.

J

Jayryght

0
Aug 19, 2016
11
Toronto, Canada
  • Aug 21, 2016
  • Add bookmark
  • #19

@wjr75 Thanks for the tip but I know verrrry little about electrical work and I don't even know what an alligator clip jumper wire is. At this point I may bite the bullet and call a tech. Kudos for your help though.

ps0303

0

TFP Expert

In The Industry

Jul 6, 2011
4,177
FL
  • Aug 22, 2016
  • Add bookmark
  • #20

Yes if you don't know much about electric or gas, call a tech and have them check it out.

Enjoying this content?

Support TFP with a donation.

Give Support

You must log in or register to reply here.

Raypak heater "Rollout SW Open" (2024)

FAQs

What does SW open mean on Raypak pool heater? ›

The sw water error is telling you the flow of water through the heater is not sufficient to start the heater. This is typically due to a dirty filter. If a sand filter backwash. If a cartridge or de filter remove and clean.

How do you troubleshoot a Raypak pool heater? ›

Go make sure there aren't any tripped circuit breakers in the fuse box, then check that the unit's time clock is set to the “On” position. Check Filters & Strainers: Problems with slow or inefficient heating, as well as overly noisy operation, can sometimes be traced back to dirty filters and strainers.

What causes a rollout switch to open? ›

The flame rollout sensor will only trip if the furnace has an underlying problem, such as blocked vents, overheating, or gas pressure issues. Ensure that you don't opt to keep resetting the switch and keeping the furnace running.

How long should a Raypak pool heater last? ›

The average life of a pool heater is between 15 and 25 years with regular usage and proper maintenance, but there are various factors that impact that projection. To make your pool heat pump last as long as possible, stick to proper usage and emphasize maintaining the system.

Why does my Raypak pool heater keep shutting off? ›

If one day you wake up and your pool heat pump stops running, the first thing to check is your water flow. Without an adequate source of water, a pool heat pump automatically shuts down to prevent overheating. This is sometimes the cause of what many describe as a pool heat pump turning off and on.

What is the purpose of a rollout switch? ›

The flame rollout switch is a safety feature that shuts off the gas supply to the burner if the flame blows out. This can happen for several reasons, such as a dirty burner or a blocked flue. A flame rollout can also be caused by a faulty gas valve or a problem with the electrical igniter.

Why does my pool heater spark but not light? ›

Check the Pilot Light

If there is no spark, you may need to replace your ignition control (you can test it first with a voltmeter to see if it has enough voltage). If you see a spark but the pilot still does not light, you may have a faulty gas valve, clogged pilot assembly, or poor ventilation.

What does SW open mean on a pool heater? ›

Pool and Spa Expert: garrygoeson. garrygoeson : When your heater is displaying "Water Switch Open", it does not always require the pressure switch to be adjusted.My first suggestion is to thoroughly clean the filter, and make certain the pump basket and skimmer basket is clean of any leaves or debris.

How do you know if your pool heater is bad? ›

Top 6 Signs Your Pool Heater Needs to be Repaired
  • Inconsistent Heating. One of the most obvious signs that your pool heater requires attention is inconsistent water temperature. ...
  • Unusual Noises. ...
  • Reduced Water Flow. ...
  • Visible Leaks. ...
  • Rust or Corrosion. ...
  • Keeps Shutting Off.
Jan 11, 2024

Why is my pool heater not blowing hot air? ›

It could also be that your pool filter is clogged or broken, the filter valve is not open, or the temperature of your heater is not set properly. If the issue is that your pilot won't light, then it could be low gas pressure, poor air supply, or improper venting.

What does roll out switch mean? ›

The flame rollout switch is a safety feature that shuts off the gas supply to the burner if the flame blows out. This can happen for several reasons, such as a dirty burner or a blocked flue. A flame rollout can also be caused by a faulty gas valve or a problem with the electrical igniter.

Is the flame rollout switch normally open or closed? ›

The flame rollout switch is normally closed and opens on high temperature from the flame. The switch is meant to open if the flame is pushed backward away from the heat exchanger area where the flame should be traveling toward. When the switch opens, the control board stops sending power to the electrical gas valve.

References

Top Articles
Multicopy The Communication Company Utrecht Centrum
How to Find a 2004 CRV Serpentine Belt Diagram? A Comprehensive Guide
Trivago Manhattan
Maria Lima Lietz - Hamburger SV
Craigslist In Lakeland
Amazon Warehouse Locations - Most Comprehensive List 2023
Memphis Beauty 2084
Europese richtlijn liften basis voor Nederlandse wet - Liftinstituut - Alles voor veiligheid
They Cloned Tyrone Showtimes Near Showbiz Cinemas - Kingwood
Pga Us Open Leaderboard Espn
/hypno/ - Hypnofa*ggotry
Mta Bus Time Q85
Nissan 300Zx For Sale Craigslist
Quest Diagnostics Bradenton Blake - Employer Drug Testing Not Offered
Ella And David Steve Strange
Cosmoprof Jobs
Regal Cinema Ticket Prices
Bones And All Showtimes Near Tucson Spectrum 18
Wayne State Dean's List
Apria Healthcare - 26 Reviews - Sacramento, CA
Cocaine Bear Showtimes Near Harkins Cerritos
suggest - Englisch-Deutsch Übersetzung | PONS
Dimbleby Funeral Home
Dr. Katrina (Katrina Hutchins) on LinkedIn: #dreambig #classof2025 #bestclassever #leadershipaugusta
Craigslist Eugene Motorcycles
Omniplex Cinema Dublin - Rathmines | Cinema Listings
Bx9 Bus Schedule
Qmf Bcbs Prefix
10 Best-Performing Bi-Directional Scan Tools in 2023 (Full Control)
Louisiana Physical Therapy Jurisprudence Exam Answers
Bureaustoelen & Kantoorstoelen - Kantoormeubelen | Office Centre
Marukai Honolulu Weekly Ads
Marissa.munoz17
Locals Canna House Deals
David Mayries
Hmnu Stocktwits
10-5 Study Guide And Intervention Tangents Answer Key
Is Arnold Swansinger Married
Gun Mayhem Watchdocumentaries
Did You Hear About Worksheet Answers Page 211
Every film that has won the Oscar for best picture
Stephanie Ruhle's Husband
Premier Nails Lebanon Pa
Easy Homemade Eggnog is So Underrated
NO CLUE: deutsche Übersetzung von NCT 127
Stafford Rotoworld
Dean of Students | Alcohol & Drug Policies
Empire Of Light Showtimes Near Santikos Entertainment Palladium
Poopybarbz
Motorsports Nation | Powersports Dealer in Waterford, CT
Keystyle.hensel Phelps.com/Account/Login
Timothy Warren Cobb Obituary
Latest Posts
Article information

Author: Carmelo Roob

Last Updated:

Views: 5515

Rating: 4.4 / 5 (65 voted)

Reviews: 80% of readers found this page helpful

Author information

Name: Carmelo Roob

Birthday: 1995-01-09

Address: Apt. 915 481 Sipes Cliff, New Gonzalobury, CO 80176

Phone: +6773780339780

Job: Sales Executive

Hobby: Gaming, Jogging, Rugby, Video gaming, Handball, Ice skating, Web surfing

Introduction: My name is Carmelo Roob, I am a modern, handsome, delightful, comfortable, attractive, vast, good person who loves writing and wants to share my knowledge and understanding with you.